SLA2X is an unit suitable for the connection with capacitance and ultrasonic level transmitter. It display the input analog variable and depending of model, it can provide 2 or 4 relays. Each threshold can be programmed with different kinds of hysteresis. Two analog exit 0÷10V and 4÷20mA, and RS232 or MODBUS serial port are available again depending of the model. Designed to be mached with 4-20mA transmitter, it is specially used to be directly connected to TC22, TC26 e TC30 capacitance level transmitter, furthermore the ultrasonic transmitters 2-wire METER can be powered directly from the SLA2X. A special function allows a remote self-calibration facility; it can memorized empty-situation by press a pushbutton and the level-condition (from 20 to 100%) pressing another pushbutton. This function can help during the calibration when using capacitance transmitter and is not easy to change the level from 0 to 100% as riquired from capacitance transmitter. The level measurement can be converted into volumes or weights, and an optional linearization system can convert to engineering units a level not commensurate with the volume. 

· Suitable for any transmitter 4-20mA

· Wide versions range

· Front panel mounting (std.)

· 24Vdc, 24/115/230/Vac power supply

· IP40 or IP54 or IP66 mechanical proof


0.00
0.00
  
商品描述

SLA2X is an unit suitable for the connection with capacitance and ultrasonic level transmitter. It display the input analog variable and depending of model, it can provide 2 or 4 relays. Each threshold can be programmed with different kinds of hysteresis. Two analog exit 0÷10V and 4÷20mA, and RS232 or MODBUS serial port are available again depending of the model. Designed to be mached with 4-20mA transmitter, it is specially used to be directly connected to TC22, TC26 e TC30 capacitance level transmitter, furthermore the ultrasonic transmitters 2-wire METER can be powered directly from the SLA2X. A special function allows a remote self-calibration facility; it can memorized empty-situation by press a pushbutton and the level-condition (from 20 to 100%) pressing another pushbutton. This function can help during the calibration when using capacitance transmitter and is not easy to change the level from 0 to 100% as riquired from capacitance transmitter. The level measurement can be converted into volumes or weights, and an optional linearization system can convert to engineering units a level not commensurate with the volume. 

· Suitable for any transmitter 4-20mA

· Wide versions range

· Front panel mounting (std.)

· 24Vdc, 24/115/230/Vac power supply

· IP40 or IP54 or IP66 mechanical proof



Case
panel mount 48x96 frontal IP40; frontal windows IP54; wall mounting execution IP66
Case material Noryl
Keyboard
4 membrane pushbuttons
Display
5+1 digit, max displayed value +-99999
LEDs 4 red
Connections
2 terminal strips, 12 pole
Power supply
24 115 230Vca, 24Vdc; ±10% depending on model
Power consumption 3,3VA (3W)
Measuring input
4÷20mA Ri = 100ohm
Self-calibration input IN1, IN2 max 18Vdc, 4mA
Data memory
EEPROM
Transmitter supply output 24Vdc-45mA max
Alarm limits (opt.)
2 or 4 with relays depending on model
Relays rating (opt.) 5A 250V
Analog exit (opt.)
0÷10V (min.1Kohm) o 4÷20mA (max.500ohm)
Serial port (opt.)
RS232 or MODBUS
Converter resolution
±20000 punti
Linearity 0,0025%
Operating temperature
-10°C ÷ +50°C
Conformity to CEE guidelines 93/68 CEE

Manuale Operativo

Operating Manual