工艺控制及测量
温度仪表
AGRITHERM40

AGRITHERM40

The PC software AGRITHERM40 communicates via USB port and an interface serial modul USB/RS485, with the multiplexers MUX. The multiplexers MUX supply the multipoint thermometric probes that detect the temperature of the single measuring point and change the temperature value read into a digital signal suitable for transmission through RS485. The PC software AGRITHERM40 , in order to identify the location of the single temperature value read, use the following addressing logic:

a) every multiplexer MUX has an identification number UID; on the same serial line can not be

a) two or more MUX with the same identification number UID;

b) every multiplexer MUX has 8 channels numbered from 1 to 8; every thermometric probe is

b) identified by the channel number of the MUX to wich it is connected;

c) the measurig points of the thermometric probe are numbered; the sensor n.1 is the nearest to

c) the probe terminal strip.

The temperature detection is achieved by:

- sensors PT100, NI100 or NI10 (specify in order) for probes type TH;

- digital sensors for probes type TT.

Every model of multiplexer MUX has several characteristics:

- mod. MUX; max n.8 probes type TT with max. n.250 detection points.

- mod. MUXA; max n.8 probes type TH with max. n.4 detection points.

- mod. MUXC; max n.8 probes type TH with max. n.8 detection points.

- mod. MUXD; max n.8 probes type TH with max. n.12 detection points.

There are versions with messages in the following other languages: Italian; French; Spanish; Russian

For Windows XP, Vista and 7 32/64bit

Up to 62 MUX concentrators connection (max total: 496 TT probes with 12 points)

PC Relay card optional

Integrated datalogger function


0.00
0.00
  
商品描述

The PC software AGRITHERM40 communicates via USB port and an interface serial modul USB/RS485, with the multiplexers MUX. The multiplexers MUX supply the multipoint thermometric probes that detect the temperature of the single measuring point and change the temperature value read into a digital signal suitable for transmission through RS485. The PC software AGRITHERM40 , in order to identify the location of the single temperature value read, use the following addressing logic:

a) every multiplexer MUX has an identification number UID; on the same serial line can not be

a) two or more MUX with the same identification number UID;

b) every multiplexer MUX has 8 channels numbered from 1 to 8; every thermometric probe is

b) identified by the channel number of the MUX to wich it is connected;

c) the measurig points of the thermometric probe are numbered; the sensor n.1 is the nearest to

c) the probe terminal strip.

The temperature detection is achieved by:

- sensors PT100, NI100 or NI10 (specify in order) for probes type TH;

- digital sensors for probes type TT.

Every model of multiplexer MUX has several characteristics:

- mod. MUX; max n.8 probes type TT with max. n.250 detection points.

- mod. MUXA; max n.8 probes type TH with max. n.4 detection points.

- mod. MUXC; max n.8 probes type TH with max. n.8 detection points.

- mod. MUXD; max n.8 probes type TH with max. n.12 detection points.

There are versions with messages in the following other languages: Italian; French; Spanish; Russian

For Windows XP, Vista and 7 32/64bit

Up to 62 MUX concentrators connection (max total: 496 TT probes with 12 points)

PC Relay card optional

Integrated datalogger function



Manuale Operativo

Operating Manual