工艺控制及测量
物位仪表
CLS7

CLS7

Rope electrode capacitance for heavy-duty application in the ON-OFF level detection for bulk-solids, granulates and powders. IP65÷66, installation on the top of the tank.

· Level measurement with medium contact

· For bulk-solids, granulates and powders measurement 

· PTFE or PVC Lining

· Threaded, flanged and sanitary connections

· IP65 / 66 / 67 mechanical protection

· Maximum length 3m

0.00
0.00
  
商品描述

Rope electrode capacitance for heavy-duty application in the ON-OFF level detection for bulk-solids, granulates and powders. IP65÷66, installation on the top of the tank.

· Level measurement with medium contact

· For bulk-solids, granulates and powders measurement 

· PTFE or PVC Lining

· Threaded, flanged and sanitary connections

· IP65 / 66 / 67 mechanical protection

· Maximum length 3m


Versions
Compact, remote
Process connection
Threaded, flanged
Mechanical protection
IP65 / 66 / 67
Electronic inserts
TL31R; TL41; TL41 ATEX; TC73R
Electrodes
Uncovered or completely PE covered Ø8mm rope
Certifications Zone 20/21 ATEX cert. (TL41 insert only)

TL31R
TL31R inserts are capacitance switches able to make the level control. The capacitance electrode (rod or rope) and the tank wall (when conductive) form a capacitor. The capacitance of the above condenser change the value proportionally to the product level changing. The capacitance variation is converted into an electrical signal able to drive the relay commutation.
· Capacitive principle point level
· SPDT relay output
· Electrostatic discharge protection
· Set-point Calibration through graduated trimmer
· 24Vdc, 24/115/230Vac power supply


TL41R
TL41.R inserts are capacitance switches able to make the level control. The capacitance electrode (rod or rope) and the tank wall (when conductive) form a capacitor. The capacitance of the above condenser change the value proportionally to the product level changing. The capacitance variation is converted into an electrical signal able to drive the relay commutation.
· Capacitive principle point level
·  SPDT relay output
·  Electrostatic discharge protection
·  ATEX certified
·  set-point Calibration through 2 push buttons
·  20÷30Vdc/24Vac or 85÷250Vac Power Supply



TC73R
TC73R insert in designed to be lodged into capacitance electrode head connection. TC73R is a multiple level control based on capacitance principle, electrode and the tank wall (if conductive) form a capacitor that has a capacitance function of the product level. The capacitance is converted into an electrical signal that drives the relays output.
· Capacitive principle point level
·  3 SPDT relays output
·  Electrostatic discharge protection
·  3 set-point Calibration through graduated trimmers
·  24Vdc power supply



Opuscolo

Brochure

Opuscolo versione ATEX
物位开关