Capacitance ON-OFF rod sensor, general purpose ON-OFF rod sensor for powders, conductive and non-conductive liquids, IP65÷67 protection, top and lateral tank mounting.
· Level measurement with medium contact
· For liquids and powders measurement
· PTFE or PVC Lining
· Threaded, flanged and sanitary connections
· IP65 / 66 / 67 mechanical protection
· Protezione IP65 / 66 / 67
· ATEX certified versions availability
· Maximum length 3m
Capacitance ON-OFF rod sensor, general purpose ON-OFF rod sensor for powders, conductive and non-conductive liquids, IP65÷67 protection, top and lateral tank mounting.
· Level measurement with medium contact
· For liquids and powders measurement
· PTFE or PVC Lining
· Threaded, flanged and sanitary connections
· IP65 / 66 / 67 mechanical protection
· Protezione IP65 / 66 / 67
· ATEX certified versions availability
· Maximum length 3m
Versions |
Compact, with spacer-cooling-fins, separate |
Process connection |
Threaded, flanged, sanitary |
Mechanical protection |
IP65 / 66 / 67 |
Electronic inserts |
TL31R; TL41; TL41 ATEX; TC73R |
Electrodes |
PTFE or PVC partially or fully insulated rigid rod |
Maximum electrodes length |
3m |
Certifications |
Zone 20/21 ATEX cert. (TL41 insert only) |
TL31R |
TL31R inserts are capacitance switches able to make the level control. The capacitance electrode (rod or rope) and the tank wall (when conductive) form a capacitor. The capacitance of the above condenser change the value proportionally to the product level changing. The capacitance variation is converted into an electrical signal able to drive the relay commutation. · Capacitive principle point level · SPDT relay output · Electrostatic discharge protection · Set-point Calibration through graduated trimmer · 24Vdc, 24/115/230Vac power supply |
|
TL41R |
TL41.R inserts are capacitance switches able to make the level control. The capacitance electrode (rod or rope) and the tank wall (when conductive) form a capacitor. The capacitance of the above condenser change the value proportionally to the product level changing. The capacitance variation is converted into an electrical signal able to drive the relay commutation. · Capacitive principle point level · SPDT relay output · Electrostatic discharge protection · ATEX certified · set-point Calibration through 2 push buttons · 20÷30Vdc/24Vac or 85÷250Vac Power Supply |
|
TC73R |
TC73R insert in designed to be lodged into capacitance electrode head connection. TC73R is a multiple level control based on capacitance principle, electrode and the tank wall (if conductive) form a capacitor that has a capacitance function of the product level. The capacitance is converted into an electrical signal that drives the relays output. · Capacitive principle point level · 3 SPDT relays output · Electrostatic discharge protection · 3 set-point Calibration through graduated trimmers · 24Vdc power supply |
|